Bacharach Tru Pointe Spécifications Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
Tru Pointe® 2100 Instruction 0028-9003
4
Physical Description
To begin using the Tru Pointe® 2100, rst take a moment to become familiar with the unit’s
controls.
ON/OFF
BAR GRAPH DISPLAY
TOUCH PROBE SENSOR
& SOLID PROBE
AIRBORNE SENSOR &
FOCUSING CONE
ALPHA-NUMERIC DISPLAY
MODE SELECTOR
UP/DOWN & SELECT
HEADSET JACK
(SIDE)
Airborne Sensor Detects external ultrasonic sound traveling through
the air, such as pressurized gas leaks, vacuum leaks,
external system noise and the SoundBlaster®. The
optional nose cone narrows the eld of view of the
sensor.
Touch Probe
Sensor
Detects internal system sounds such as internal valve
leaks, bearing wear and faulty steam traps.
Bar Graph Display Shows relative strength of detected signal in bar graph
format and includes a Peak/Hold feature.
Power Button Turns the Instrument On/Off
Alphanumeric
Display
Level/Mode indicator. Displays active mode, current
mode setting and numeric intensity reading. Also
indicates when battery power is low.
Mode Select Button Scrolls through menu options for adjustment/selection
Up Adjustment Increases a setting or scrolls through mode options
Down Adjustment Decreases a setting or scrolls through mode options
Headphone Jack For headphone plug