Bacharach Monoxor III Spécifications

Naviguer en ligne ou télécharger Spécifications pour Détecteurs de monoxyde de carbone (CO) Bacharach Monoxor III. Bacharach Monoxor III Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 10
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
MONOXOR
II
INSTRUCTION 0019-9113
Portable CO Analyzer
Part No. 0019-7034 & 0019-7039
Rev. 8 - May 2010
Bacharach, Inc.
621 Hunt Valley Circle, New Kensington, PA 15068
PH: 1-800-736-4666 • FAX: 724-334-5001 • Web: www.mybacharach.com
Printed in U.S.A. ® Registered Trademarks
®
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Portable CO Analyzer

MONOXOR IIINSTRUCTION 0019-9113Portable CO AnalyzerPart No. 0019-7034 & 0019-7039Rev. 8 - May 2010Bacharach, Inc.621 Hunt Valley Circle, New Ken

Page 2 - WARRANTY

7 HAZARDS OF CARBON MONOXIDECarbon monoxide poisoning results in headache, nausea, chronic tired-ness, confusion, dizziness, and sometimes coma or de

Page 3 - 1 INTRODUCTION

WARRANTYBacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in mater ial and manufac ture and will c

Page 4 - FOR OPERATION

1WARNING!Because this instrument is used to detect and monitor materials and conditions which are listed by OSHA or others as potentially hazardous to

Page 5 - 3.2 Probe Installation

2Figure 2. Battery Installation2 TECHNICAL CHARACTERISTICSCO Display Range ... 0-1999 ppm COAccuracy ... ±10 p

Page 6 - 4.2 Zeroing the Instrument

Figure 3. Probe Installation3If batteries are accidently installed in the wrong polarity, a positive temperature coeffi cient (PTC) thermistor will pro

Page 7 - 4.6 Interpreting the Display

44 OPERATIONTo operate the Monoxor II, you simply . . .• Set its POWER switch to ON, • Wait for the instrument to warm up (approx. 1 minute), • Ze

Page 8 - 5 MAINTENANCE

54.3 Backlight ON/OFFThe LCD can be read in low-light areas by setting the front panel LIGHT switch to ON. The backlight stays on until turned off, o

Page 9 - 6.1 Parts/Accessories List

6Overrange When the gas sample exceeds 1999 ppm, a “1” is displayed on the LCD. To clear an overrange condition, leave instrument turned on and samp

Page 10 - 7 HAZARDS OF CARBON MONOXIDE

6 PARTS / SERVICE6.1 Parts/Accessories List Item Part No. Battery Cover 0019-3029 Probe/Hose/Line Dryer Assy. 0019-3084 Flexible Probe Tube (