Bacharach Fyrite INSIGHT PLUS Manuel d'instructions Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 116
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
Overview Fyrite
INSIGHT
Plus Manual
4 0024-9487 Rev 2
Feature North American (NA) versus Siegert (S) Configurations
Countries
Typical North American
(NA) Users
Typical
Siegert (S) Users
Asia Belgium
Australia Denmark
Latin America France
North America Germany
South America Italy
Netherlands
Poland
Spain
United Kingdom
Heating Values For combustion calculations, Siegert uses the fuel’s lower
heating value; NA uses the higher value (see page 66).
Fuels Different fuel sets and composition (see page 24)
Different RUN
Parameters
EFF (NA) vs. Stack loss and ETA (S)
Excess Air (NA) vs. Lambda (S)
(Lambda is similar to excess air) (see page 66)
Extra Siegert
Parameters
CO/CO
2
ratio, boiler temperature, smoke number, and oil
derivative are displayed for Siegert only (see page 66).
CO
2
Max In the Siegert configuration, the user can set a CO
2
Max number
for the fuel (see page 24).
Print Average
Feature
There is a print average feature for Siegert (see page 32).
Time and Date
Format
NA: MM/DD/YY w/ 12-hour time format with AM/PM or
DD/MM/YY w/ 24-hour time format (see page 49)
Siegert: DD/MM/YY w/ 24-hr time format only
Languages 3 for the North American (NA) configuration and 8 for the
Siegert (S) configuration (See language list on page 46)
NOTE: The Combustion Equations setting is used to configure the
instrument to use either North American combustion equations or
Siegert combustion equations (see page 52). Changing this setting
resets memory and the values of other settings. Refer to page 52
for a list of affected parameters.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 115 116

Commentaires sur ces manuels

Pas de commentaire