1.2.2 General Warnings & Cautions
• Always inspect the sample hose before each use. Replace the hose if it appears cracked,
frayed, obstructed or fouled with oil.
• ALWAYS turn the compressor off before connecting the instrument to an air conditioning
system.
• Always wear eye and skin protection when working with refrigerants. Escaping refrigerant
vapors will present a freezing danger.
• To reduce the risk of electrical shock, do not disassemble the instrument; do not use the instru-
ment in wet or damp areas.
• DO NOT direct refrigerant vapors venting from hoses towards the skin.
• DO NOT disassemble the instrument. There are no serviceable components internal to the
instrument and disassembly will void the warranty.
• ALWAYS place the Identifi er on a fl at and sturdy surface.
• DO NOT utilize any other hose other than those supplied with the instrument. The use of other
hose types will introduce errors into the refrigerant analysis and instrument calibration.
• ALWAYS verify that the refrigerant to be tested does not contain or will not emit heavy loads of
oil or liquid.
• NEVER admit any sample into the instrument at pressures in excess of 500 psig.
• NEVER obstruct the air intake, sample exhaust or case vent ports of the instrument during use.
1.3 Features and Capabilities
The Pur•Chek™ Pro HVAC Diagnostic Refrigerant Analyzer is the most advanced portable instrument ever
manufactured for determining the purity of gaseous refrigerants for the HVAC-R market. Features of the
Pur•Chek™ Pro include:
• Unprecedented thirteen (13) infrared (IR) detection system
• Advanced ergonomic design
• Rugged rubberized hand grips
• Large graphic display with on-screen instructions
• Fast 3 minute test time
• Built-in printer for instant analysis report
• Vapor or liquid sampling ability
• Internal, rechargeable battery option for cordless operation in any location
• Hard shell carry/storage case
• Remote software update port
1.4 Pur•Chek™ Pro Model and Contents
Model Name Part Number Contents
Pur•Chek™ Pro 2100-8003 Pur•Chek™ Pro ...................................... 2100-8002
1/4” Flare Vapor Sampling Hose ............ 2100-0008
1/4” Flare Liquid Sampling Assembly ..... 2100-0009
AC Adapter ............................................. 2100-0004
Printer Paper (1 Roll) .............................. 2100-0003
Instruction Manual .................................. 2100-9001
Spare Sample Hose Filter ...................... 2100-0010
All contained in a hard shell storage/carrying case.